Download the appropriate Unified Service Desk client setup file. Sign in as a user with local Administrators group membership, and then double-click the downloaded file to begin Setup. The Unified Service Desk client installer starts automatically. On the Unified Service Desk screen, keep the default location or enter the complete path where the Unified Service Desk client application files will be installed, and then click Next.
The Microsoft. Unified Service Desk. Because Unified Service Desk is the core component of setup, you cannot continue unless it is selected. Create a desktop shortcut for Unified Service Desk. By default, a shortcut will be created for easy launching of the Unified Service Desk client from the desktop. The next screen shows the installation status of the Unified Service Desk client. When you are prompted to authorize the installation as a result of User Account Control , click Yes. A confirmation message appears on successful installation of the Unified Service Desk client.
On a computer where a previous version of the Unified Service Desk client is installed, sign in to the computer as a user with local Administrators group membership, and then double-click the SetupUnifiedServiceDesk. When setup detects the previous version of the Unified Service Desk client, you'll see the following information:.
An older version of Unified Service Desk is already installed on your computer. Setup will upgrade Unified Service Desk on your computer. A confirmation message appears on successful upgrade of the Unified Service Desk client. Instead, you supply the required information at the command prompt. This example installs or upgrades the Unified Service Desk client in silent mode, creates a shortcut on the desktop.
This example uninstalls the Unified Service Desk client. Skip to main content. This browser is no longer supported. Download Microsoft Edge More info. To install and operate the switch successfully, ensure compliance with the following requirements:.
For successful installation and operation of the switch, ensure that the following environmental requirements are met:. All equipment in the rack should force air in the same direction to avoid intake of exhaust air. Consult your fan and power supply module FRU kit to determine the correct configuration. Before installing the device, plan its location and orientation relative to other devices and equipment.
Devices can be mounted in a standard inch equipment rack or on a flat surface. The ICX should not be installed upside down. As with any equipment, a filter or surge suppressor is recommended. For successful installation and operation of the switch in a cabinet, ensure the following cabinet requirements are met:. Do not rely on a secondary connection to a branch circuit, such as a power strip. Cables can be organized and managed in a variety of ways; for example, use cable channels on the sides of the cabinet or patch panels to reduce the potential for tangling the cables.
The following list provides some recommendations for cable management:. Before plugging a cable to any port, be sure to discharge any static charge stored on the cable by touching the electrical contacts to ground surface.
You should not use tie wraps with fiber-optic cables because they are easily overtightened and can damage the optical fibers. Velcro-like wraps are recommended.
This provides room to remove and replace the switch, allows for inadvertent movement of the rack, and helps prevent the cables from being bent to less than the minimum bend radius. Follow the steps listed in Table 3 to install your device. Details for each of these steps are provided on the pages indicated. Make sure the airflow around the front and sides of the device is not restricted. Risk of explosion if battery is replaced by an incorrect type. Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over.
Use a separate branch circuit for each AC power cord, which provides redundancy in case one of the circuits fails. Ensure that the device does not overload the power circuits, wiring, and over-current protection.
To determine the possibility of overloading the supply circuits, add the ampere amp ratings of all devices installed on the same circuit as the device. Compare this total with the rating limit fo the circuit. The maximum ampere ratings are usually printed on the devices near the input power connectors.
Disconnect the power cord from all power sources to completely remove power from the device. If the installation requires a different power cord than the one supplied with the device, make sure you use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the device.
Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox.
Please check your email for further instructions. Enter a new password. All Rights Reserved. About This Guide Audience. Audience This document is designed for system administrators with a working knowledge of Layer 2 and Layer 3 switching and routing.
Document conventions This section describes text formatting conventions and important notice formats used in this document. Text formatting The narrative-text formatting conventions that are used are as follows: bold text Identifies command names Identifies the names of user-manipulated GUI elements Identifies keywords Identifies text to enter at the GUI or CLI italic text Provides emphasis Identifies variables Identifies paths and Internet addresses Identifies document titles code text Identifies CLI output For readability, command names in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow.
Command syntax conventions Command syntax in this manual follows these conventions: command Commands are printed in bold. For example, --show WWN Boolean. Elements are exclusive. Example: --show -mode egress ingress Notes, cautions, and danger notices The following notices and statements are used in this manual. NOTE A note provides a tip, guidance, or advice, emphasizes important information, or provides a reference to related information.
CAUTION A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware, firmware, software, or data. Notice to the reader This document might contain references to the trademarks of the following corporations. These references are made for informational purposes only.
Additional information This section lists additional Brocade and industry-specific documentation that you might find helpful. Document feedback Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and completeness of this document.
Forward your feedback to: documentation brocade. No power supplies, fan units, or expansion module need to be ordered separately. Advanced software. No optics. Brocade ICX customizable models The Brocade ICX base systems do not ship with power supplies or fans, these are ordered separately to allow for building the system that meets your network needs.
Brocade ICX slot and Ethernet port numbering 1 Brocade ICX slot and Ethernet port numbering Many CLI commands require users to enter port numbers as part of the command syntax, and many show command outputs display port numbers. Location considerations Before installing the device, plan its location and orientation relative to other devices and equipment. Recommendations for cable management Cables can be organized and managed in a variety of ways; for example, use cable channels on the sides of the cabinet or patch panels to reduce the potential for tangling the cables.
The following list provides some recommendations for cable management: CAUTION Before plugging a cable to any port, be sure to discharge any static charge stored on the cable by touching the electrical contacts to ground surface.
Installation tasks Follow the steps listed in Table 3 to install your device. Guide 7 Before attaching equipment to the device, you must configure Brocade ICX Administration an interface IP address to the subnet on which the device will Guide be located. Guide 10 Continue configuring the device using the CLI. Installation precautions 2 Installation precautions Follow all precautions when installing a device. Lifting precautions CAUTION Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over.
CAUTION Before plugging a cable to any port, be sure to discharge any static charge stored on the cable by touching the electrical contacts to ground surface. CAUTION If the installation requires a different power cord than the one supplied with the device, make sure you use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country.
Installing the device in a rack or cabinet CAUTION Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over.
You can only view or download manuals with. Sign Up and get 5 for free. Upload your files to the site. You get 1 for each file you add. Get 1 for every time someone downloads your manual. Buy as many as you need. View and download manuals available only for.
Register and get 5 for free. Upload manuals that we do not have and get 1 for each file. Get 1 for every download of your manual. Buy as much as you need. E-mail: info brocade. Brocade Communications Systems Co. Shenzhen WFOE. E-mail: emea-info brocade. Recommendations for cable management.
Fixed values following arguments are printed in plain font. For example,. Example: --show -mode egress ingress. W AC power supply; power-supply-side exhaust port-side intake airflow.
W AC power supply; power-supply-side intake port-side exhaust airflow. W DC power supply; power-supply-side exhaust port-side intake airflow. W DC power supply; power-supply-side intake port-side exhaust airflow.
Brocade ICX fan kit of 4, exhaust airflow.
0コメント