Endoscan v manual


















For example, a technology approved with a decision for 7. Anything - 7. However, a 7. Anything , but would not cover any version of 7. For example, a technology approved with a decision for Appropriate access enforcement and physical security control must also be implemented. References The following reference s are associated with this entry: Type Name Source Description There are no references identified for this entry.

Technology Components Note: This list may not be complete. No component, listed or unlisted, may be used outside of the technology in which it is released. The usage decision for a component is found in the Decision and Decision Constraints. Name Description No components have been identified for this entry.

General Analysis Adoption Benefits This is a mature, well-documented technology. This technology is not portable as it runs only on Windows Client platforms. Go to site. EndoScan-V is an endotoxin data collection, analysis, and reporting software. This technology has not been assessed by the Section Office. Charles River. The Vendor Release table provides the known releases for the TRM Technology, obtained from the vendor or from the release source.

Decision Constraints. Technology must remain patched and operated in accordance with Federal and Department security policies and guidelines in order to mitigate known and future security vulnerabilities. VA Categories. It does not contain any parts that can be maintained, repaired, or replaced by the user. Doing so may cause fire or electric shock. Doing so may damage interior components and may cause fire or electric shock.

Doing so may damage cord and cause injury. Provide the MCS reader with power by connecting the provided power cable to the entry module of the reader and the grounded mains outlet. During operation of the MCS reader the lateral venting slots must not be blocked. Also the cooling fan in the back of the MCS reader must not be blocked at any time.

Please ensure a 50 mm safety clearance on the left, right and back side of the instrument. Cartridges can now be used according to our cartridge package inserts. Please hold the cartridges as shown below. The warranty period will start on the date of shipment by Charles River Laboratories. During the warranty period, Charles River Laboratories will repair the instrument at no charge to the client for parts and labor. If repairs are needed, Charles River Laboratories will provide the client a loaner instrument during the period the instrument is being repaired.

The client shall be responsible for all freight charges associated with the returned instrument and the loaner instrument.

Opening the case or tampering with the interior components of the reader will invalidate warranty provisions. All goods returned for repair, preventative maintenance, or calibration, whether under warranty or not, must be properly packed to avoid damage and clearly marked with the RGA number. All warranty and service options are subject to the Terms and Conditions and procedures specified in the Service Agreement. Install EndoScan-V software. Once successfully connected to a MCS Reader the following screen will appear.

This will show all available bays for each instrument connected. Change Spike recovery range to 50 to 6. Enter the Cartridge lot number. The Cartridge lot number will be stored for later use. Enter the Calibration code. The Calibration code will be stored for later use.

Enter product information by either typing directly into the box or by dragging information from the product database into the dialog box. Enter the concentration or dilution. Insert the cartridge into the bay. While in progress the screen will display messages showing the current status.

Upon completion of the assay a message will be displayed instructing the user to remove the cartridge and a screen similar to the one below containg data for the assay will be displayed. Select the report option to print a report for this assay.

Select the save or save as option to save the assay as an EndoScan-V file. The screen will display a message asking to save an individual assay or all assays that have been completed. Select the desired method. Assay is now saved as an EndoScan-V file. The following represents a typical assay procedure: 1. Insert the Cartridge O n y l n Note: Allow the cartridge to come to room temperature in pouch before use. Remove cartridge from pouch and insert with sample reservoirs facing up into one of the slots at front of the MCS Reader o i t a Press cartridge firmly into slot 3.

While the above information is being entered into the reader, the cartridge is being pre-warmed. When the test is complete, the results will be displayed on screen.

O n The software continues to display the assay results until the new assay button is selected.